A slater opening an eave for a fascia repair finds loose insulation piled several feet back from the outside wall. Topping up the low spot may leave the same wind path in place. Before closing the eave, ask the insulation contractor to identify the boundary that keeps the fill in position and the separate passage that admits ventilation air.
In a vented attic with ceiling-level insulation and a soffit intake, the wind dam retains the insulation at its outer edge. The baffle preserves a passage toward the underside of the roof. The Department of Energy describes using these together in rafter bays supplied by soffit vents. Missing protection can let incoming wind shift insulation away from the perimeter. Thin insulation alone does not establish the cause.
Inspect from the intake toward the attic
Have the trades mark the bays exposed by the slate work and which ones actually serve as intakes. For each open bay, ask for a photo showing where the insulation stops, what retains it and where ventilation air passes above it. A photo of even insulation depth taken from the middle of the attic can miss a blocked intake at the outer edge.
For example, if only four bays were exposed beside a dormer, label those four on the handover sketch. Leave the concealed bays unverified. Have the designer review the roof assembly before adding vents to an older building or applying this vented-attic detail to an insulated roof slope. For a wider investigation, the attic thermal survey guide explains how to record the conditions behind a thermal image.