An attachment file for a clay or concrete tile roof may contain a picture of a sample of cured foam and a line that says “ratio checked.” Each entry answers a different question. When the project calls for documentation of a two-part adhesive, ask the qualified applicator to identify the measurement behind the ratio.
For Polyset AH-160, ICP’s instructions describe calibration before application and define the ratio as the net weight of component A divided by the net weight of component B. Container weights matter. If a paper cup and its contents are weighed together, the total includes the cup unless the scale was tared. A handwritten pair of numbers without units, component labels or a tare record can be hard to interpret months later.
Read a sample entry
For illustration, recorded net masses of 55 grams of A and 50 grams of B give an A-to-B ratio of 1.10. Reversing the labels gives about 0.91. The same pair of numbers now tells a different story. Keep the original values, the product and equipment identification, the applicator’s name and the time of the check. Ask the project reviewer to compare the result with the instructions that apply to that equipment and approval.
The same AH-160 instructions also call for test samples during tile placement. Identify the courses or area associated with those checks so a reviewer can distinguish initial calibration from observations made as work proceeded. Where a separate field uplift report is required, file that result under its own heading. A correctly transcribed mix ratio alone cannot establish the attachment strength of an installed tile.