Preserving the craft. Building its future.

Clay and concrete tile · Stormwater investigations

Can a sample from the downspout identify what came off the roof tile?

Give a stormwater consultant the route rain took across tile, flashing and gutters before assigning a measured metal to the roof covering.

By the Slate, Tile & Metal Guild ·

A stormwater report identifies a sample as “clay roof” because the collector stood beneath the downspout of a tiled wing. That label leaves out every other surface the water crossed. Before a facilities manager replaces tile in response to a metal reading, the consultant needs a better description of what was sampled.

Washington’s Department of Ecology tested runoff from a concrete tile panel alongside other roofing panels and glass controls. Its comparison with earlier concrete tile studies found little agreement across most reported metal concentrations. The report also records an important qualifier for one published clay tile result from Switzerland: the building had old copper gutters. Those details tell a reader which comparisons are possible. They do not identify the source of copper at a different building.

Follow the water to the sample point

Start with a roof and drainage plan. Shade the surfaces draining to the sampled outlet, including any upper roof discharging onto the tiles. Along the route mark exposed valleys, flashings, gutter liners and downspout materials where known. Circle the precise collection point. Water taken after two downspouts join represents both branches. A sample taken from storage has also passed through the collection system. The Guild’s guide to connected roof area helps establish which surfaces contribute.

Give the consultant that annotated plan, the collection date, recent maintenance and any changes since collection. Describe the finding as a measurement at the identified outlet during that event. If the decision turns on which material contributed the metal, ask the consultant to design a comparison that can distinguish the suspected sources. That is a different investigation from repeating a sample at the same mixed outlet.

Further reading

Washington State Department of Ecology — Roofing Materials Assessment, publication 14-03-003, Tables 1 and 28. InspectAPedia hosts this copy of Ecology’s February 2014 primary research report. The panel results illustrate sample interpretation and provide no water-use clearance or prediction for a particular roof.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles