A skylight looks as if it will fit on the upper part of a slate slope. Its frame clears the ridge on the elevation. The metalwork uphill of the frame still needs a place to go. Before ordering the unit, set out the top of the back pan on the roof section and see what occupies that space.
The Roofing Contractors Association of British Columbia describes a back pan that carries water from the uphill side of a skylight or chimney around its sides. Its slate detail calls for the pan to continue at least 600 mm under the uphill slates and at least 75 mm beyond the obstruction at each side. A hypothetical layout with only 450 mm of slope left above the uphill face would be 150 mm short of that detail even before allowing for work at the ridge. Measuring to the top edge of the glass instead of the uphill face would put the starting point in the wrong place.
Draw the metal that disappears
Ask for a section along the slope and a plan showing the curb, pan and side outlets. Mark the lower edge of the ridge assembly on the same section. Give each dimension its own endpoints. Where the two assemblies overlap on paper, take that drawing to the designer and skylight supplier while the opening can still move. Moving the opening may affect the framing or daylight layout, so record the agreed position before cutting.
A proprietary flashing kit can have different dimensions and limits. Identify the selected unit and kit on the drawing. The Guild guide to roof-window flashing depth and grouping covers a separate check on the sides of the opening.