A roof elevation shows two windows stacked one above the other in a slate slope. A later architectural detail lowers the frames to reduce their prominence. The frame sizes and positions on the elevation look unchanged. The flashing schedule deserves another look.
FAKRO lists two installation depths for its EL family of flashings for slate roofs. At its V depth the manufacturer lists horizontal pairs, vertical combinations and blocks. At J depth, three centimetres lower, the same product page lists horizontal combinations only. A side-by-side pair and a pair stacked up the slope are therefore different ordering questions even when both windows have the same dimensions.
Review the elevation and section together
Give the supplier a small elevation with an arrow toward the ridge, plus a cross-section showing the proposed frame depth at the slates. Include the slate thickness, roof pitch, window dimensions and proposed spacing. FAKRO’s table also distinguishes permissible pitches by installation depth. A dimensioned elevation alone cannot establish whether the selected kit covers the arrangement.
If a vertical pair is specified at J depth, ask for a documented compatible detail or a design revision before the openings are framed. Have the architect choose between the available options with the exterior appearance and interior opening in view. Keep the confirmed combination reference in the slate roof window file. That way the window order and the flashing order describe the same roof.