Preserving the craft. Building its future.

Slate · Sheet metal

Does the copper flashing submittal identify the temper?

Check sheet weight and temper separately when reviewing copper for fabricated flashings on a slate roof.

By the Slate, Tile & Metal Guild ·

The shop quotes twenty-ounce copper for flashings around a slate dormer. The purchasing sheet repeats the same weight beside every part, from straight apron to shaped corner. When the fabricator asks which temper was specified, the sheet gives no answer. A weight in ounces per square foot tells the shop how much metal there is per unit area. Temper is a separate material property relevant to forming.

Revere’s architectural guide specification illustrates the distinction. It lists several ounce weights for standard sheet copper and identifies H00 as the default temper unless the documents indicate otherwise. Its mechanical properties table distinguishes soft copper from several cold-rolled tempers. The mere presence of “twenty-ounce” in both a specification and a quotation leaves the temper comparison open.

Keep the part number with the material description

Consider a repair that combines a straight apron with a formed return where the dormer cheek meets the eaves. Ask the shop to identify the detail number, sheet weight, proposed temper and finish on each line. If the shop wants a different temper for the shaped return, have it flag that particular part and the forming reason. The designer can review the change without inadvertently changing every straight length on the order.

A mock-up can settle the appearance of the corner, but it records little about the stock if the sample arrives unlabelled. Keep its material designation with the approved drawing and compare the production stock identification before fabrication. For the separate question of how a quoted ounce weight affects quantity, see the Guild’s valley sheet weight example.

Further reading

Revere Copper Products · Classic Copper, architectural guide specifications and mechanical properties. The guide specification describes the manufacturer’s product. The project documents and the particular fabrication detail control selection.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles