A downspout shown on the front of a slate-roofed house would cover part of a window surround. Moving it a few feet on the elevation looks simple. On the gutter shop drawing, though, the new position may fall on the other side of an expansion joint.
The Copper Development Association explains that the expansion joint in the gutter arrangement it describes interrupts water flow. The trough can look continuous from the street while the two sections drain separately. Increasing the diameter of the relocated downspout would do nothing for water trapped on the other side of that division.
Follow the water from each end
On the gutter plan, distinguish soldered splices from movement joints. Start at each high point and pencil an arrow down the gutter fall. Every arrow should reach an outlet serving that section. If one ends at the joint, ask the designer to revise the outlet, the falls or the joint layout together. Add any concentrated flow from a slate valley to the section that actually receives it.
Return the marked plan to the sheet-metal shop before it cuts the outlet opening. The slater also needs the agreed layout if a change affects the eave apron under the first courses. Keep the drainage plan alongside the separate record of which liner seams can be tested in the shop.