A supplier sends a spreadsheet with the entry “Estate S, adhesive, 87.” A reviewer could easily read the number as pounds of pull or as wind pressure. The heading in the original approval supplies a crucial piece of information that the spreadsheet lost.
In table 6 of Miami-Dade notice 26-0227.02, attachment resistance is expressed as a moment in foot-pounds force. A moment describes a turning effect. It depends on both force and its distance from the axis of rotation. A pressure in pounds per square foot, a pull in pounds and a resisting moment are different quantities. Comparing their bare numbers can make an unsupported assembly appear to pass.
Carry the whole row into the review
For the named Estate S profile, table 6 lists a single-patty Polyset AH-160 configuration at 54 grams with a resistance of 87 ft-lbf. Another row for the same adhesive at 24 grams gives 46 ft-lbf. The shared product name therefore cannot identify the quoted resistance. The table also points the reader to the component approval for installation requirements.
Ask for the tile identification, approval number, table, attachment configuration, resistance and units on one line. Give that line to the project designer for comparison with the corresponding calculated demand. If the only demand supplied is a roof-zone pressure, request the project calculation that connects it to the tile moment. Keep the resulting design decision separate from the field uplift test record.