A submittal for a concrete S-tile roof includes a sketch of a wire-tie system and an evaluation report for a deck anchor. The two sheets answer different questions. Before accepting the substitution, trace the connection on the sketch from the tile all the way to the deck. Then check where the report starts and ends.
Detail MC-27 in the Tile Roofing Industry Alliance manual shows a set clip, wire and deck anchors. It directs the reader to the anchor manufacturer's ICC-ES report for the installation of the deck anchors. The same drawing says Uniform ES has not evaluated the illustrated specialty system and identifies it as outside the roof tile evaluation reports. The manual's cover report number therefore cannot establish approval of this entire wire-tie arrangement.
Mark which interface each document supports
On the contractor's drawing, identify the tile and clip at one end and the anchor and proposed deck at the other. Beside the anchor, record the product designation, supporting material and installation conditions from the cited report. For example, if the report page supplied describes only an anchor in concrete, it leaves a question open for a proposed wood deck. Record that question against the anchor line so a replacement report can be checked against the same location.
Ask the party responsible for the attachment design to identify what supports the wire-to-clip connection, how the anchorage layout addresses the project's design loads and which approval covers that combination. A substitution review can then distinguish a missing report page from a missing system design. Once the design is resolved, the field attachment closeout guide addresses how to record the installation.