A ceiling plan shows a round daylight diffuser marked “14 inches.” A second drawing repeats the circle on the concrete tile roof. Before the roofer sets aside tiles or anyone lays out a cut, ask which part of the unit each circle represents. The manufacturer can call out different openings at the two ends of a single tube.
For its 14-inch flexible pitched TMF model, VELUX USA lists a ceiling rough opening of 15¼ inches and a roof-deck rough opening of 12½ by 16 inches. One nominal product size has produced two different dimensions and two different shapes. Neither opening specifies the width of the finished area of tile work around the dome.
Give the ceiling and roof crews the same section
Show the diffuser location on the reflected ceiling plan and the dome on the roof plan. Label the level beside each rough-opening dimension. Where the projected centers differ, have the installer trace the tube route through the intervening space and check obstructions. The product page describes a flexible tube but leaves the installer to verify that a particular route fits.
On the roof detail, identify the concrete tile profile and the selected flashing. VELUX lists tile flashing as available for the TMF. Ask the supplier to identify what the order includes and provide the matching tile detail before the roofer establishes the area to open. Keep that sheet with the roof penetration records so a later tile repair can identify the assembly.