On a concrete barrel-tile house, the owner proposes removing a damaged length of gutter and letting that eave drain freely. The first drawing revision erases the gutter line. It leaves the tiles and the perforated strip beneath their noses exactly as drawn. For a wind-exposed building, that revision deserves a second look.
In full-scale tests of tile roofing systems, the Insurance Institute for Business & Home Safety and its research partners examined wind pressures on roof tiles. IBHS reports that vented bird stops can increase the vulnerability of edge tiles to uplift and that a gutter or a sealed bird stop can reduce that vulnerability. A bird stop is the closure beneath the tile ends at the eave. The finding makes the shape of the entire roof edge relevant to a gutter change. It supplies no universal uplift credit for an existing gutter.
Show what the redesign takes away
Give the designer a section through the affected eave showing the tile profile, closure openings, fascia, gutter rim and edge-tile fastening. Mark the full length being removed and the point where the retained gutter begins. Photographs from the ground can help distinguish the two sections. Obtain concealed information from the project records or a qualified roofer.
Ask for a decision on the edge assembly under the proposed configuration. Include how runoff will discharge and whether any openings serve ventilation or drainage. Filling a perforated closure on site would change those functions as well. Keep the reviewed section with the gutter work order so a later contractor can identify the intended drainage openings in the tile closure.