A designer asks for a dark roof that will look even above a pale stone entrance. A supplier sends a thermal-cycle test marked T1. Before signing the sample card, read what the letter and number describe. A laboratory classification and a landscape architect’s preference for an unmarked entrance answer different questions.
Welsh Slate’s published commercial sheet for its Cwt-y-Bugail County grade reports T1. Its interpretation allows surface oxidation of metallic minerals and changes of color that leave the slate’s structure intact and produce no streaking in the test. The sheet distinguishes T2, where discoloration can run while the structure stays intact. Those descriptions concern the specimen after testing. A fleck on a sample alone cannot establish a test category or predict what caused a streak on a building.
Record the visual decision in its own words
Keep the dated technical sheet with the exact stone and grade offered. Beside it, record what the owner accepted on the sample panel. If occasional visible metallic flecks are acceptable on the main slope but the elevation above the entrance needs further review, mark that location and settle the selection with the supplier before ordering. The approving party then has a visual record to revisit if a delivery raises questions. See Slate Roofing USA’s guide to reading slate test reports.