A roof plane measures 8 metres along the eave and 5 metres up the slope. That gives the roofer 40 square metres of covering to account for. It also gives a solar designer a starting rectangle. Using the whole 40 as the generating area can overstate what the owner will get, even on a roof with no chimneys or windows.
GB-Sol’s UK integrated PV Slate system uses ordinary or non-generating infill slates around its perimeter. The manufacturer suggests allowing roughly half a metre around edges and penetrations when first estimating the available area. Applying that allowance on all four sides of the example leaves a 7-by-4-metre rectangle. That is 28 square metres before the designer fits whole modules into it. The remaining 12 square metres still need a roof covering.
Ask for two counts on the same elevation
Have the solar designer mark each active unit and its rated output. Ask the roofer to identify the natural slates and any matching infill pieces around that field. A roof window introduces an additional boundary, so arithmetic based only on the four outside edges will need revision. Use the selected system’s dimensions and project-specific design to settle the order. See Slate Roofing USA’s guide to preparing the natural slate order.