Preserving the craft. Building its future.

Slate · Flashing takeoff

Does a wider replacement slate change the metal order at the wall?

Recheck the concealed wing of each soaker when wider slates are substituted beside a rising wall.

By the Slate, Tile & Metal Guild ·

A supplier offers wider slates of the same length for a small roof against a brick wall. The architect approves the appearance and the slater confirms the course spacing. There is still a question for the sheet-metal shop: will the pieces already cut to flash the wall extend far enough beneath the wider stone?

In Welsh Slate’s illustrated side-abutment detail, each course has a soaker, a bent piece of lead with one leg against the wall and one beneath the slate. The stepped flashing covers the upright legs. The detail sizes the under-slate wing using the greater of 100 millimetres and half the slate width. The dimension is measured across the roof surface from the wall. A 100-millimetre wing and a 100-millimetre total blank are two different orders.

Price the effect of an approved substitution

For a hypothetical change from 200- to 250-millimetre-wide field slates, the wing in that detail increases from 100 to 125 millimetres. The height of the upright leg is a separate dimension. Mark both legs on the folded section and have the metalworker confirm the blank. Along the slope, the manufacturer relates soaker length to the course gauge and lap. Check those against the revised layout as well, even when slate length stays constant.

Do this while the metal is still on the cutting list. Record which roof-to-wall runs use the new slate width, which pieces have already been formed and who will revise the order. The Slate Roofing USA guide to renewing flashings gives owners a starting point for discussing the surrounding work when a sidewall is opened.

Further reading

Welsh Slate · Roofing brochure, Abutments, sloping edge, p. 24. This example uses the sloping-edge detail for the Welsh Slate system illustrated. It does not prescribe a universal soaker dimension.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles