A chimney marked 24 by 42 inches on a slate reroof drawing leaves a question for the estimator. Which face meets water coming down the slope? A cricket is the small peaked structure on the uphill side that directs water around the chimney. Under section R903.2.2 of the 2024 International Residential Code, a chimney needs a cricket or saddle when its width across the slope exceeds 30 inches.
Draw an arrow from ridge toward eave on the roof plan. Suppose the 42-inch side runs across that arrow. The chimney exceeds the threshold in this provision. Rotate the identical rectangle a quarter turn and the cross-slope width becomes 24 inches. That dimension alone no longer triggers this provision. The area of the opening stayed exactly the same.
Send both bidders the oriented sketch. Ask the designer to confirm the locally adopted code, project requirements and flashing detail before comparing allowances for metalwork and slates around the chimney. For the adjacent work, see Slate Roofing USA’s guide to planning chimney service.