Preserving the craft. Building its future.

Slate roofing · Snow retention submittals

Which part of the slate determines the reach of a retrofit snow guard?

Use the concealed part of the slate to check the strap dimension on a model-specific snow guard drawing.

By the Slate, Tile & Metal Guild ·

A photo of the roof gives the supplier a clear view of the exposed slate courses. It does not show how far a retrofit strap must reach to engage the head of a slate. Two slopes with the same visible margin can have different slate lengths and different amounts of stone hidden above the margin.

Alpine SnowGuards’ drawing for its PD10R distinguishes the strap length, labeled L, from the hook dimension, labeled T, and from the overall length of the finished guard. The instructions determine L using the concealed slate length plus three times the thickness of the slate. They give separate guidance for the hook. A catalog measurement taken from the tip of the hook to the outer end of the pad cannot stand in for L.

Check the dimension lines before ordering

Consider two surveyed roof areas with the same exposure and slate thickness. If the slates in the second area are two inches longer, two more inches are concealed there. Under this particular formula the required strap reach increases by those same two inches. A single detail copied across both areas could conceal the mismatch until the guards arrive.

Have the roofer establish the slate dimensions at each proposed location from available records, a verified spare or an appropriate site inspection. Send the supplier a sketch showing the full length, exposed margin and thickness beside the actual product drawing. Keep its fit confirmation alongside the slate snow-retention plan. A strap that can reach its intended engagement point still needs a design for the roof conditions, guard positions and loads.

Further reading

Alpine SnowGuards · PD10R and related models, product submittal, pre-installation dimensions. These dimensions belong to the named product. The project designer and manufacturer determine layout and suitability.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles