Look down an open metal valley on a slate roof and the two cut edges may spread apart gradually toward the eave. A dimension reading “widen by one inch” is easy to misread. The distance between the slates and the distance from one cut edge to the valley centerline are two different measurements.
The National Slate Association’s sample specification describes setting the slates back on each side of the centerline and increasing the opening toward the bottom to help ice release. It refers the metal fabrication to a separate section. The exposed strip between the slates gives only part of the information needed to order the metal beneath them.
Show an upper and a lower cross section
Consider a hypothetical symmetrical detail. The upper opening is six inches in total, three inches on each side. An instruction to increase the setback by one inch on each side produces an eight-inch opening below. An instruction to increase the whole opening by one inch produces a seven-inch opening. On the latter detail each edge moves only half an inch. Both readings could come from the same casually worded note.
Ask the designer to mark the centerline, the two slate cut edges and the total exposed opening at each end. Have the slater and fabricator check those dimensions against the specified valley metal and the parts it must cover beneath the stone. The two marked sections also give the crew a reference for checking the layout before cutting the valley slates. Keep them with the roof section drawings.