A caliper reads 10 mm on a loose slate. The approved sheet says 9 mm. Before treating that millimetre as a delivery error, read the heading above the number. Two adjacent rows on a declaration can answer different questions.
Read the second thickness row
Welsh Slate’s January 2025 declaration for its Cwt-y-Bugail Celtic roofing slate identifies 9 mm as the nominal thickness. Its individual-thickness entry also gives a percentage variation around that value. For perspective, 10 mm differs from 9 mm by about 11 percent. That arithmetic shows why a difference from nominal, taken alone, cannot settle a complaint. It does not establish that someone measured the specimen by the applicable method or that an entire lot meets the project requirements.
Record the declaration number, product and grade beside the crate identification. Note who measured the piece, where on it the reading was taken and whether the measurement was requested by the supplier. Ask the supplier to identify the applicable method before comparing a series of readings. If the design calls for a tighter selection to meet an adjoining roof or flashing detail, find that requirement in the approved order too. The declaration describes the product. The job documents establish which selection the buyer requested.
When the job is a repair, record the dimensions of the existing piece separately from those of the proposed replacement. The Slate Roofing USA matching resource explains what to include with the photographs.