How many sizes of flashing belong in a graduated slate valley?

Use the approved course exposures to group concealed valley flashing blanks for the sheet-metal shop.

By the Slate, Tile & Metal Guild ·

A metalworker receives one closed-valley flashing pattern for a graduated slate roof. The long slates near the eave and the shorter slates farther up have different exposures. Before cutting a pile of identical pieces, compare the proposed blank with the course schedule. Each flashing is laid into the slate work as its course goes on.

In its closed-valley guidance, the National Slate Association gives a general flashing length based on the exposed course height plus the headlap, with another one to two inches. Check the overlap on the laid-out valley as well. The guide calls for successive flashing pieces to overlap by at least three inches, with slope and climate potentially calling for more. The guidance treats width separately. A dimension across the valley tells the shop nothing about how long each concealed piece needs to be up the valley.

Separate the order at a change of exposure

Consider two illustrative course groups on a detail for which the designer selects an extra two inches. At nine inches of exposure and three inches of headlap, the calculation gives a fourteen-inch piece. At seven inches of exposure with the same headlap and extra length, it gives twelve inches. Carrying the upper group’s shorter pattern down to the eave would lose two inches against this example’s design.

Ask the slater to mark the first and last course in each group, count the pieces against the approved layout, and identify transitions or end conditions requiring individual patterns. Label the shop bundles by valley and course range. Before this exercise, check that the proposed closed valley suits the adjoining slopes. The schedule sizes blanks for a selected detail. It cannot resolve a mismatch between the roof planes.