A designer wants daylight in a loft and a small interruption to the slate slope seen from the street. Those two aims call for two measurements. The external frame dimensions help draw the window in elevation. The area admitting daylight comes from a different entry in the product sheet.
Take the CC04 size in VELUX’s UK Heritage conservation range. The frame is 550 mm wide and 978 mm high. Multiplying those figures gives about 0.54 square metres for the frame rectangle. The manufacturer lists 0.33 square metres of effective daylight area for that size. For the taller CC06 with the same 550 mm width, its figure is 0.42 square metres. The proposed increase in daylight area is therefore 0.09 square metres. That comparison tells you how much larger the effective glazed area is. Room brightness also depends on the window’s position and the space below.
Give each drawing the measurement it needs
Show the external frame and the proposed flashing outline on the slate elevation. Beside the loft plan, list the effective daylight area for each alternative. Ask the architect to compare the effect inside with the additional height visible outside. For a local project, use the data sheet for the exact window offered in that market. Keep the roof window and adjacent slate selections together in the material submittal review.