Preserving the craft. Building its future.

Concrete tile · Skylight replacement

Why a skylight and its concrete-tile flashing kit can carry different size codes

Use a curb-mounted skylight example to check a tile flashing quotation against the manufacturer’s size table, roof pitch and existing curb.

By the Slate, Tile & Metal Guild ·

A replacement quote for a skylight in a high-profile concrete tile roof lists a 2234 curb-mounted unit and an ECW kit marked 2246. Should someone change the purchase order so the numbers match? First ask for the flashing chart. With this VELUX system, a single kit size can serve several skylight lengths of the same width.

Read across the kit row

In the manufacturer’s ECW brochure, 2234 appears among the covered sizes on the 2246 kit row. That pairing has a documented explanation. It does not establish that a particular opening meets every condition for using the kit. ECW is intended for specified curb-mounted skylights, standard-size site-built curbs and high-profile coverings. The brochure specifies roof pitches from 14 to 60 degrees. The raised curb and the roof slope beneath it are separate things to measure.

Imagine two curb-mounted skylights on the same house. The main roof and porch have the same concrete tile, and both skylights carry the same size code. If the porch pitch measures 10 degrees, finding its code in the size table leaves an unresolved application issue. Ask the supplier or designer for a documented flashing solution for the porch before approving a pair of identical kits.

Resolve the opening before releasing the order

Give each opening a separate line on the quote. Ask the installer to record the skylight model, the curb dimensions the product drawing calls for, roof pitch at that opening, and the tile profile. Attach the size-chart row or manufacturer detail supporting the selection. Have the contractor identify whether the existing curb will stay or be rebuilt, since measurements for the old curb alone cannot describe a replacement.

The homeowner can review the two schedules from the ground. Leave field measurements and opening-up to the professionals doing the work. Tile Roofing USA’s underlayment guide provides background for discussing how the roofer will reconnect the layers around the opening.

Further reading

VELUX USA — ECW tile flashing kit, application limits and size table. The example uses the named curb-mounted flashing system. Check current model-specific instructions for the actual opening.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles