When a specification asks for a Health Product Declaration for concrete roof tile, copy the words that follow the concentration into the review notes. A requirement of 100 parts per million per material has a different meaning from 100 parts per million per product. The HPD Open Standard allows both bases for reporting.
Run the numbers for a thin finish
Suppose a finish represents two percent of a tile’s mass. An ingredient present at 500 ppm by weight in that finish contributes 10 ppm to the whole tile, assuming it appears nowhere else. On a 100 ppm per-material basis, it crosses the reporting threshold in the finish. Using the same numerical threshold across the whole tile, it falls below it. The ingredient and its amount stayed the same. The denominator changed.
This is an illustrative calculation. For an actual selection, identify the offered product and finish, obtain the applicable declaration and read the inventory method and threshold for each relevant material. Eagle Roofing Products’ HPD page points readers toward declaration records. Record the document version and date so the reviewer can find the same inventory.
If the specification and declaration use different bases, flag the exact difference for the architect. A missing ingredient entry alone cannot establish absence. Keep this review distinct from a recycled-content calculation, which answers a different procurement question.