A contractor prices “30-pound felt” under the concrete tile. The supplier offers a less expensive roll labeled “No. 30.” Before anyone approves the saving, put the roll wrapper beside the underlayment schedule. A familiar number on the front leaves a question about the sheet inside.
Eagle’s technical bulletin distinguishes asphalt-saturated felt made to ASTM D226 Type II from utility-grade products sold under a similar description. It also identifies ASTM D4869 Type IV as a designation encountered for tile underlayment. The type number belongs with its particular standard. A buyer who copies only “Type II” has left out half the identification.
Trace the proposed roll to the specified assembly
Suppose the signed specification expressly calls for ASTM D226 Type II. Put those words in the first column of the purchase review. In the second, enter the manufacturer, product name, standard and type from the proposed roll and its data sheet. If the supplier identifies a different standard, send that product through the project’s substitution review. If the wrapper only gives a nominal weight, ask for the product documentation that establishes the classification.
Keep the layer count and covered area beside the product identification when comparing tile reroof bids. A sheet that matches the requested material can still arrive in the wrong quantity for the specified assembly. At delivery, photograph a wrapper with the product name visible and file it with the accepted data sheet. That gives the owner a record of what went under the tile after the empty wrappers leave the site.