An architect asks for the concrete tile’s permeability documentation. The supplier sends a product sheet with a water absorption percentage. The number looks responsive because both properties concern water. A reviewer who pastes it into the permeability row has silently changed the question.
Absorption concerns the water a specimen takes up. Permeability concerns passage through the specimen under the stated test conditions. ASTM’s public summary of C1492-22 names both among the properties tested for concrete roof tile. A value for one leaves the result for the other unresolved.
Make the missing item easy to answer
Suppose a substitution package contains the profile name, a photograph and a laboratory table headed “Water absorption.” In the review log, record that table against absorption. In the permeability row, ask for the document and page that report the result for the proposed product under the specified edition. Quote the profile designation from the offer so the supplier can check whether the evidence supplied covers that tile. If the project accepts a declaration of conformity, identify it as such and follow the project’s submittal requirements.
This distinction also helps with leak complaints. A laboratory result for an individual tile cannot locate the entry path at a valley, penetration or lap on an installed roof. Keep the product report with the material record and send observations about the installed assembly to the roofer separately. If the roof contains several generations of tile, the Tile Roofing USA identification guide can help establish which product the report needs to cover.