Preserving the craft. Building its future.

Concrete tile · Drawing review

Does a 3-in-12 concrete tile roof fall inside a 15-degree trim range?

Convert a roof section’s rise per foot to degrees before comparing it with the pitch range for a proposed mono-ridge fitting.

By the Slate, Tile & Metal Guild ·

A roof section marks a single-slope porch as 3:12. A trim sheet gives the minimum pitch in degrees. The 12 in the drawing is the horizontal run: the roof rises three inches for every twelve inches measured level. To compare the drawing with the sheet, calculate the angle whose tangent is 3 divided by 12. In degree mode, a calculator gives about 14.0°.

Check the fitting named on the quote

Marley’s UK product page for its 457 mm modern concrete mono stop end ridge lists a pitch range of 15° to 50°. A 3:12 roof falls below that particular fitting’s stated range. At 4:12 the same calculation gives about 18.4°, inside the published range. That resolves one question about this fitting. Compatibility with the field tile, edge detail and fixing system still needs the designer’s review.

On an actual bid, write the roof section number, slope in both units and exact trim model on the same line of the roof accessory schedule. Where the proposed fitting falls outside its range, request a detail for the specified roof slope before releasing the order. Use the supplier’s data for the product proposed locally. Marley’s figures illustrate the calculation for one UK fitting.

Further reading

Marley — Concrete 457 mm modern mono stop end ridge, function and compatibility. See the cited source for the scope of its guidance.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.