The roof tile schedule can settle the color of a chimney pot. It leaves two questions unanswered about a working masonry fireplace. Will the base fit the flue it serves, and is the opening at the top suitable for that fireplace? Two pots with similar silhouettes can have different internal dimensions.
Give each flue its own line on the order
On a stack with several outlets, label each flue on a drawing and have the chimney professional identify what it serves. For a working fireplace, record the fireplace opening dimensions, flue dimensions and shape, and the proposed pot model. Request a drawing showing its internal base dimensions and the clear opening at its narrow top. An outside diameter on a catalog elevation cannot answer either fit question on its own.
Superior Clay’s selection guidance relates the pot base to the flue and the top opening to the fireplace opening. Ask the project’s chimney professional to confirm the selection for the particular fireplace and venting system. If the outlet serves an appliance, identify the appliance and its permitted termination before specifying any pot. A photograph of an adjacent working fireplace does not establish suitability.
Suppose two flues on one elevation call for the same glazed finish. Release the color sample for both if it is acceptable, but keep the model choice open for any flue whose use or dimensions are unknown. For a separate ridge ornament with a similar silhouette, use the guide to identifying a clay smoke louvre or finial before adding it to the fireplace schedule.