A buyer reviewing replacement clay tiles finds “150 cycles” in the frost test paperwork. It is tempting to put 150 years into the owner’s maintenance forecast. Start instead with three entries in the laboratory report: what arrived, when it was inspected and what counted as damage.
In report UK23913-6102, Lucideon describes six plain clay tiles selected by its client. The laboratory recorded existing defects and conditioned the specimens before freeze-thaw testing. It examined them at 30, 90 and 150 cycles under the specified European test method. These are successive inspections of the test specimens. Adding the three checkpoints together would inflate the test exposure.
Keep the result attached to the specimens
The report includes a damage classification table. A hair crack and a break occupy different categories. A buyer who reduces the table to “any visible mark is a failure” loses the distinction the laboratory actually used. Ask the supplier to identify the specimen results, the acceptance criterion and the connection between the tested samples and the offered product. When the proposal combines new field tile with reclaimed fittings, identify which line item the report supports.
For the owner’s file, enter the method, final checkpoint and reported condition in a test-results field. Reserve a separate line for any warranty term the supplier actually offers. The laboratory sequence gives no conversion from cycles to calendar winters on this roof. For a cold-region project, ask the designer to evaluate the proposed tile and roof details against the site exposure, including any manufacturer requirements for severe conditions.