A roofing estimate covers a whole slope in clay. A separate solar quote covers a rectangle on the same drawing. Where the proposed modules form part of the roof covering, adding the two quotes together can leave the owner buying ordinary tiles for space already occupied by modules.
Take one manufacturer’s system as a worked example. Solinso describes its TerraCotta-748 as a 38-watt-peak module that occupies the position of three matching clay tiles. It lists three specific Nelskamp profiles. For a layout with 24 of these modules, the solar installer would count 24 electrical units, the roofer would mark 72 displaced field-tile positions, and the nameplate total would be 912 watts peak. The peak rating alone cannot tell the owner how much electricity the roof will deliver over a year.
Use one marked elevation for both orders
Have the designer identify every active module on a copy of the accepted course layout. Mark ordinary tiles retained around the array, including areas beside roof windows, and list spare tiles separately. Ask each trade to sign off on its own quantities using the same revision. If a module moves from one slope to another, issue the new layout to both trades so the change reaches both orders.
The three-to-one conversion belongs to that module and the listed clay profiles. For another system, obtain the working dimensions, matching profile and approved arrangement for the project. Carry the agreed deduction into the roof tile and accessory schedule.