At a sloping roof-to-wall joint, the sawtooth line visible on the masonry can hide a second set of flashings. In a traditional double-lap plain tile detail, each course has a small folded piece called a soaker. One leg lies beneath the tile and the other turns up the wall behind the cover flashing.
For the detail shown in its UK sitework guide, Marley sizes the soaker length from three dimensions. A 100 mm course gauge, the distance between successive courses, combines with a 65 mm headlap and a 25 mm turn at the head to give a 190 mm blank along the slope. A shop reading only the gauge from the tile layout would leave out 90 mm in this example. The wall upstand and the width of metal beneath the tile are separate dimensions across the blank.
Send the shop a dimensioned side view
Ask the roofer to identify the accepted gauge and headlap at the actual wall. Mark the head of the tile and the fold on the section. In the takeoff, count the courses meeting the wall and record any different pieces at the ends. A single line item in linear feet can conceal both the number of cuts and their length.
Use the metal, folds, laps and exposure allowed for the locally specified assembly. Keep the proposed soaker alongside the tile sample and the clay roof tile submittal so the roofer and sheet-metal shop review the same detail.