Preserving the craft. Building its future.

Slate code and specifications

A slate bid changes the underlayment. What happens to its Class A claim?

Use a New York City code example to check the deck and underlayment behind a bid’s external-fire classification.

By the Slate, Tile & Metal Guild ·

Two bidders offer the same natural slate for a building with a wood roof deck. One names an ASTM D226 Type II underlayment. The other proposes a synthetic sheet and carries over the first bidder’s Class A claim. What document would justify that change?

New York City’s 2022 Building Code gives a concrete example. Section 1505.2 includes slate on noncombustible decks among its Class A exceptions. It separately identifies slate over a combustible deck when ASTM D226 Type II underlayment lies between them. A wood deck brings that underlayment line into the review. A product description that says only “synthetic” leaves its qualification unanswered.

For a project using that provision, ask the second bidder for the proposed product’s data and the basis for the exact assembly’s classification. A listing that covers the proposed layers may provide another route. Have the designer check the applicable code before accepting the substitution. The bid comparison can then identify exactly which assembly each price buys. See Slate Roofing USA’s guide to performance claims.

Further reading

New York City Department of Buildings — 2022 Building Code, section 1505.2, exceptions 2 and 4. See the cited source for the scope of its guidance.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.